Search results for "instrumentation [Diffusion Magnetic Resonance Imaging]"
showing 10 items of 2402 documents
Improved measurement of $^8$B solar neutrinos with $1.5 kt·y$ of Borexino exposure
2017
We report on an improved measurement of the $^8$B solar neutrino interaction rate with the Borexino experiment at the Laboratori Nazionali del Gran Sasso. Neutrinos are detected via their elastic scattering on electrons in a large volume of liquid scintillator. The measured rate of scattered electrons above 3 MeV of energy is $0.223\substack{+0.015 \\ -0.016}\,(stat)\,\substack{+0.006 \\ -0.006}\,(syst)$ cpd/100 t, which corresponds to an observed solar neutrino flux assuming no neutrino flavor conversion of $\Phi\substack{\rm ES \\ ^8\rm B}=2.57\substack{+0.17 \\ -0.18}(stat)\substack{+0.07\\ -0.07}(syst)\times$10$^6$ cm$^{-2}\,$s$^{-1}$. This measurement exploits the active volume of the …
Enhancing Light Emission in Interface Engineered Spin-OLEDs through Spin-Polarized Injection at High Voltages
2019
The quest for a spin-polarized organic light-emitting diode (spin-OLED) is a common goal in the emerging fields of molecular electronics and spintronics. In this device, two ferromagnetic (FM) electrodes are used to enhance the electroluminescence intensity of the OLED through a magnetic control of the spin polarization of the injected carriers. The major difficulty is that the driving voltage of an OLED device exceeds a few volts, while spin injection in organic materials is only efficient at low voltages. The fabrication of a spin-OLED that uses a conjugated polymer as bipolar spin collector layer and ferromagnetic electrodes is reported here. Through a careful engineering of the organic/…
Calculation of total muon flux observed by Muon Monitor experiment
2017
An approach to calculate the flux of cosmicgenic muons detected by Muon Monitor experiment in lab LAB2400 of the Underground Laboratory in Canfranc (LSC) is described. The measuring apparatus consists of three layers of SC16 scintillation matrix detectors. The hardware function of the detector assembly was determined using computer simulation. Obtained value of the total muon ux turned out to be equal to (4.35 ± 0.2) × 10−3 m −2 s −1. peerReviewed
Design and implementation of the AMIGA embedded system for data acquisition
2021
The successful installation, commissioning, and operation of the Pierre Auger Observatory would not have been possible without the strong commitment and effort from the technical and admin-istrative staff in Malargtie. We are very grateful to the following agencies and organizations for financial support: Comision Nacional de Energla Atomica, Agencia Nacional de Promocion Cientffica y Tec-nologica (ANPCyT) , Consejo Nacional de Investigaciones Cientfficas y Tecnicas (CONICET) , Gobierno de la Provincia de Mendoza, Municipalidad de Malargtie, NDM Holdings and Valle Las Leilas, in gratitude for their continuing cooperation over land access, Argentina; the Australian Research Council; Conselho…
Calibration of the underground muon detector of the Pierre Auger Observatory
2021
To obtain direct measurements of the muon content of extensive air showers with energy above $10^{16.5}$ eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 $\mathrm{m^2}$-modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m$^2$ close to the intersection of the shower axis with the ground to much less than one per m$^2$ when far away, the necessary bro…
The craniovertebral junction in rheumatoid arthritis: State of the art
2019
Rheumatoid arthritis (RA) is a chronic inflammatory disorder, characterized by polyarticular inflammation causing progressive joint damage and disability. The mechanisms underlying its pathogenesis involve activation of innate and adaptive immunity, microvascular endothelial cell activation, and inflammatory infiltration of lymphocytes and monocytes into the synovium. Spinal involvement in RA is not typical; when it occurs, the main radiological features are (1) atlantoaxial subluxation (AAS), which is the most typical form of cervical spine involvement; (2) cranial settling—also known as basilar impression, atlantoaxial impaction or superior migration of the odontoid—which is the most seve…
Long-baseline neutrino oscillation physics potential of the DUNE experiment
2020
The sensitivity of the Deep Underground Neutrino Experiment (DUNE) to neutrino oscillation is determined, based on a full simulation, reconstruction, and event selection of the far detector and a full simulation and parameterized analysis of the near detector. Detailed uncertainties due to the flux prediction, neutrino interaction model, and detector effects are included. DUNE will resolve the neutrino mass ordering to a precision of 5σσ, for all δCPδCP values, after 2 years of running with the nominal detector design and beam configuration. It has the potential to observe charge-parity violation in the neutrino sector to a precision of 3σσ (5σσ) after an exposure of 5 (10) years, for 50% o…
Astrophysical muon neutrino flux in the northern sky with 2 years of IceCube data
2015
Results from the IceCube Neutrino Observatory have recently provided compelling evidence for the existence of a high energy astrophysical neutrino flux utilizing a dominantly Southern Hemisphere data set consisting primarily of νe and ντ charged-current and neutral-current (cascade) neutrino interactions. Additionally, a fit for an astrophysical flux with an arbitrary spectral index is performed.
Search for contained neutrino events at energies above 30 TeV in 2 years of data
2013
Neutrino observations are a unique probe of the universe's highest energy phenomena: neutrinos are able to escape from dense environments that photons cannot and are unambiguous tracers of hadronic interaction processes, in particular the acceleration of cosmic rays. We report on results of an all-sky search for these neutrinos at energies above 30 TeV in the cubic kilometer antarctic IceCube observatory between May 2010 and May 2012. The search follows up on the previous detection of two PeV neutrino events, with improved sensitivity and extended energy coverage down to approximately 30 TeV.
IceCube-40 String Data: Searching for a Diffuse Flux of Astrophysical Muon Neutrinos
2011
One of the main strategies used to look for astrophysical neutrinos with IceCube is the search for a diffuse flux of high-energy neutrinos from unresolved sources. A search was performed using data from the IceCube detector collected in its half completed configuration in which 40 strings operated between April 2008 and May 2009. 12,877 candidate neutrino events were obtained from this data sample.